叶宇, 马雁潮. QSFP-DD光模块热设计研究[J]. 光通信研究, 2022,(4):47-51.
YE Yu, MA Yan-chao. Research on Thermal Design for QSFP-DD Transceiver Module[J]. Study on Optical Communications, 2022,(4):47-51.
叶宇, 马雁潮. QSFP-DD光模块热设计研究[J]. 光通信研究, 2022,(4):47-51. DOI: 10.13756/j.gtxyj.2022.04.010.
YE Yu, MA Yan-chao. Research on Thermal Design for QSFP-DD Transceiver Module[J]. Study on Optical Communications, 2022,(4):47-51. DOI: 10.13756/j.gtxyj.2022.04.010.
近年来,双密度四通道小型可插拔封装(QSFP-DD)形式的200/400 Gbit/s光模块,以其相对低功耗和体积小便于高密度部署的优势得到电信市场和数据中心市场的青睐,但高速率和小体积带来的散热条件恶化问题限制了QSFP-DD光模块的使用环境。文章采用有限元方法对QSFP-DD模块进行热学建模仿真,研究了200 Gbit/s QSFP-DD 4通道长距离(LR4)光模块在高温环境下的内部温度场,验证了导热垫对改善模块内部散热条件的效果,并实测了模块在高温环境下的性能,为QSFP-DD光模块的设计和应用提供了参考。
In recent years
200/400 Gbit/s transceiver in the form of Quad Small Form Factor Pluggable-Double Density (QSFP-DD) is favored by the market due to their relatively low power consumption and small size for high-density deployment. However
the deterioration of heat dissipation caused by high speed and small size limits the application of QSFP-DD optical modules. In this paper
the finite element method is used to conduct thermal modeling and simulation of QSFP-DD module
and the internal temperature field of 200 Gbit/s QSFP-DD Long Range 4(LR4) optical module in high temperature environment is studied. The effect of thermal pad on improving the internal heat dissipation of the module is verified. The performance of the module in high temperature environment is measured. It provides a reference for the design and application of QSFP-DD transceiver module.
双密度四通道小型可插拔封装光模块导热垫热分析
QSFP-DD optical modulesthermal padthermal analysis
Isono H. Latest Standardization Trends for Client and Networking Optical Transceivers and Its Future Directions[C]//Metro and Data Center Optical Networks and Short-Reach Links. San Francisco, California, US: SPIE OPTO, 2018: 12.2286714.
Zhang D, Zhang B, Xiao X, et al. Consideration of Datacenter Optics for 400 G and Beyond[C]//Asia Communications and Photonics Conference. Chengdu, China: IEEE, 2019: T2D.1.
Ghiasi A. QSFP-DD Hardware Specification for QSFP Double Density 8X Pluggable Transceiver[EB/OL].(2019-03-11)[2022-03-23]. https://www.qsfp-dd.com/specification/https://www.qsfp-dd.com/specification/.
蔡媛媛.高速宽带光模块电磁干扰及热设计研究[D].南京:东南大学, 2016.
杨明冬, 全本庆, 关卫林. QSFP+光收发模块的热设计研究[J]. 电子机械工程, 2017, 33(4):38-41.
马静, 李守智. 基于ANSYS的电力电子热稳态分析的研究[C]//2010年电力与能源工程学术会议. 中国,武汉: PEEC, 2010: 479-483.
答邦宁. 导热衬垫在印制板组件上的应用研究[J]. 电子机械工程, 2013, 29(3):50-52, 64.
ICT杂谈. Samtec:QSFP-DD鼠笼和散热器的热设计[EB/OL]. (2019-10-05)[2021-12-28]. https://zhuanlan.zhihu.com/p/85250640https://zhuanlan.zhihu.com/p/85250640.
0
浏览量
39
下载量
0
CSCD
关联资源
相关文章
相关作者
相关机构
鄂公网安备 42011202002092号